We are describing a new method of isolating genomic DNA from whole blood collected for plasma/serology. After plasma collection, the compacted blood is usually discarded. Our novel method represents a significant improvement over existing methods and makes DNA and plasma available from a single collection, without requesting additional blood.
Laboratory tests can be done on the cellular or fluid portions of the blood. The use of different blood collection tubes determines the portion of the blood that can be analyzed (whole blood, plasma or serum). Laboratories involved in studying the genetic basis of human disorders rely on anticoagulated whole blood collected in EDTA-containing vacutainer as the source of DNA for genetic / genomic analysis. Because most clinical laboratories perform biochemical, serologic and viral testing as a first step in phenotypic outcome investigation, anticoagulated blood is also collected in heparin-containing tube (plasma tube). Therefore when DNA and plasma are needed for simultaneous and parallel analyses of both genomic and proteomic data, it is customary to collect blood in both EDTA and heparin tubes. If blood could be collected in a single tube and serve as a source for both plasma and DNA, that method would be considered an advancement to existing methods. The use of the compacted blood after plasma extraction represents an alternative source for genomic DNA, thus minimizing the amount of blood samples processed and reducing the number of samples required from each patient. This would ultimately save time and resources.
The BD P100 blood collection system for plasma protein preservation were created as an improved method over previous plasma or serum collection tubes1, to stabilize the protein content of blood, enabling better protein biomarker discovery and proteomics experimentation from human blood. The BD P100 tubes contain 15.8 ml of spray-dried K2EDTA and a lyophilized proprietary broad spectrum cocktail of protease inhibitors to prevent coagulation and stabilize the plasma proteins. They also include a mechanical separator, which provides a physical barrier between plasma and cell pellets after centrifugation. Few methods have been devised to extract DNA from clotted blood samples collected in old plasma tubes2-4. Challenges from these methods were mainly associated with the type of separator inside the tubes (gel separator) and included difficulty in recovering the clotted blood, the inconvenience of fragmenting or dispersing the clot, and obstruction of the clot extraction by the separation gel.
We present the first method that extracts and purifies genomic DNA from blood drawn in the new BD P100 tubes. We compare the quality of the DNA sample from P100 tubes to that from EDTA tubes. Our approach is simple and efficient. It involves four major steps as follows: 1) the use of a plasma BD P100 (BD Diagnostics, Sparks, MD, USA) tube with mechanical separator for blood collection, 2) the removal of the mechanical separator using a combination of sucrose and a sterile paperclip metallic hook, 3) the separation of the buffy coat layer containing the white cells and 4) the isolation of the genomic DNA from the buffy coat using a regular commercial DNA extraction kit or a similar standard protocol.
1. Sample Collection
2.1 From blood of P100 tube (P100_DNA)
2.2 From Blood of EDTA Ttube (EDTA_DNA)
3. DNA Quantity and Quality Assessment
The quantity, quality and integrity of the genomic DNA were assessed by a combination of method that includes picogreen, spectroscopy and electrophoresis.
4. Genotyping Assays and Quality Control
DNA quality assessment and concentration measurement
The yields of P100_DNAs were significantly lower than those of EDTA_DNAs (Tables 1 and 2). The DNA purity represented by its 260/280 ratio value is similar for both P100_DNA and EDTA_DNA sample set (Tables 1 and 2). The quality of the DNA is fairly uniform within each set of sample although some degradation is seen in the EDTA_DNA samples, as indicated by light smear (Figure 2). The EDTA_DNAs that showed more signs of degradation also showed reduced DNA concentration.
Genotyping
The genotyping call rate for both EDTA_DNAs and P100_DNAs were compared. They yielded similar call rates and were both comparable to the internal HapMap control DNA (Table 3).
Figure 1. Buffy coat isolation.
Table 1. DNA sample yield (PicoGreen) and ratio (nanodrop).
DNA Yield | DNA Purity | |||
Samples | P100 | EDTA | P100 | EDTA |
1 | 135 | 340 | 1.79 | 1.9 |
2 | 119 | 344 | 1.85 | 1.89 |
3 | 57 | 129 | 1.88 | 1.88 |
4 | 159 | 640 | 1.86 | 1.88 |
5 | 140 | 430 | 1.86 | 1.88 |
6 | 150 | 673 | 1.86 | 1.9 |
7 | 139 | 425 | 1.74 | 1.88 |
8 | 118 | 240 | 1.87 | 1.86 |
9 | 51 | 86 | 1.87 | 1.83 |
p value | p = 0.00221 | p = 0.09836 |
Table 2. Comparison of yield and purity (two-tailed, Paired Sample t-test).
Genotyping Cell Rate | ||
Samples | P100 | EDTA |
1 | 97.9 | 97.5 |
2 | 97.9 | 97.8 |
4 | 97.4 | 97.5 |
7 | 97.5 | 98.2 |
8 | 97.9 | 98 |
P value | p = 0.67970 |
Table 3. Genotyping call rate (two-tailed, Paired Sample t-test).
Samples | Layers | Yield (μg) | Ratio (260/280) |
P100_06 | Buffy coat | 150 | 1.86 |
RBC | 4.13 | 1.73 | |
P100_07 | Buffy coat | 139 | 1.74 |
RBC | 1.00 | 1.70 | |
P100_08 | Buffy coat | 118 | 1.87 |
RBC | 3.72 | 1.78 | |
P100_09 | Buffy coat | 51 | 1.87 |
RBC | 0.23 | 0.98 |
Appendix. Evaluation of the amount of DNA found in red blood cell (RBC) layer.
Many human diseases have genetic causes and exploring the genetic basis of human disease demands an increasing high quality DNA. The most common source of DNA used in genetic studies is anticoagulated whole blood. Because most clinical laboratories perform biochemical, serologic, and viral testing as a first step in phenotypic outcome investigation, the blood is often collected in a plasma tube. After collection of the plasma, the compacted blood is often discarded. Therefore, when DNA is needed to conduct genetic studies or testing, an additional blood draw is required from the same patient. The discarded compacted blood represents a potential source of DNA as it contains white blood cells. Therefore, using compacted blood from plasma tubes offers an opportunity to use the collected blood sample more efficiently, without the need to draw surplus blood or recall the patient for additional blood.
Various methods to extract DNA from the white cells of compacted or clotted blood have been reported6-10. Most of the challenges of these methods were associated with the design of the plasma collection tube. Earlier plasma collection tubes contained a separator made of a gel (gel separator) which, when centrifuged, formed a barrier to separate the blood cells (trapped below the separator) from the plasma (located above the separator). To prevent contamination of the blood cells with the gel material, the separator must first be carefully removed from the tube11. This is followed by a fragmentation of the blood clot to guarantee efficient DNA extraction. The fragmentation process often results in a significant loss of blood sample and a reduction in DNA yield. To minimize sample loss and improve the process, a small-pore mesh was used to mechanically dispersed the blood clot into small pieces12, but fragmentation still affected DNA yield and quality and even constituted a health hazard to the technician13.
The BD P100 tubes from BD bioscience are the latest generation of plasma collection tubes evaluated in multicenter immunologic research study14. Like the previous plasma tubes, they contain anticoagulants to prevent coagulation and protease inhibitors to stabilize the plasma proteins. The major innovation of the BD P100 tube resides in the mechanical separator (not a gel separator) inside each tube. The mechanical separator also provides a physical barrier between the plasma and cell pellet after centrifugation, but unlike the gel separator, offers no risk of sample contamination by a gel. The protocol applied in this study does not include a fragmentation; therefore there is no health hazard risk.
The DNA was extracted from the buffy coat, using a commercial kit protocol (see DNA extraction). The compacted blood in the BD P100 tubes were cryopreserved for a period of 3 to 4 months prior to DNA extraction. DNA extracted from EDTA tubes (EDTA_DNA) were used as a control in the assessment of the yield and quality of their corresponding P100_DNA. From previous studies 12,13,15 , the yields of EDTA_DNA samples were significantly higher than that of DNA from blood of previous plasma tubes. In this study, for the same amount whole blood collected from each patient, the buffy coat of the compacted blood yielded less DNA (Table 2, p = 0.00221). During the DNA extraction from the blood in the new P100 plasma tubes, some white blood cells from the buffy coast are lost to the red blood cell layer (below it) but represents insignificant amount of DNA compared to those from the buffy coat (see appendix table). The variation in yield seen with EDTA_DNAs is also mimicked with the P100_DNA suggesting that it is sample dependent. Samples with higher volume would normally yield more DNA and samples with lower volume and/or slightly degraded DNA would yield less DNA.
Analyses on agarose gel (Figure 2) revealed that EDTA_DNAs show signs of degradation (smear) not seen in their corresponding P100_DNAs. In particular, two EDTA_DNA samples (EDTA_01053 and EDTA_06030) with the lowest yield show more smear than others. In their study, Wong et al.11 reported decreased DNA yield with increased storage time. Since all the blood samples in our repository were subjected to the same storage condition and the sample subset used in this study was randomly selected, storage length and condition are unlikely to account for the differences seen on the agarose gel between P100_DNAs and EDTA_DNAs. The fact that only EDTA_DNAs show degradation could be associated to the lack of protease inhibitors in the EDTA tubes.
The purity of the P100_DNAs and EDTA_DNAs were not significantly different (Table 2, p = 0.09836). This shows that good quality DNA can be efficiently extracted from P100 plasma tubes using a routine commercial kit. The fact that slightly degraded EDTA_DNA samples also show good purity, suggesting that purity is not a good measure of DNA sample integrity.
The samples used were recruited for the genetic studies of inflammatory bowel disease. Therefore, to compare the performance of the extracted DNA samples, the immunochip5 was selected as the genotyping testing platform. The immunochip has been used as a fine mapping genotyping platform for immunogenetics 16,17. The genome-wide nature of the SNP genotyping assays was used as a stringent measure of DNA performance. The average genotyping call rates for all DNA test and HapMap control samples, across all chips, were 97.76% and 97.4% respectively, showing comparable excellent performance of the DNA from both blood collection tubes (Table 3, p=0.67970).
Conclusion
DNA can be isolated from the compacted blood of BD P100 tubes, facilitating genomic testing from the same blood sample drawn for plasma proteomics studies. Our results extend the research utility of the P100 tube. The fact that DNA in the cellular content of blood collected in P100 is usable for genomic analyses can help simplify sample acquisition for studies in which both proteomic and genomic analyses will be performed. Therefore, less blood is needed from each human subject and an associated cost and effort savings for the study sponsors and staff is improved. There are several advantages demonstrated:
The authors have nothing to disclose.
Name of the reagent/equipment | Company | Catalogue number |
BD P100 tubes | BD Diagnostics | 366448 |
EDTA tubes | BD Diagnostics | 367863 |
Sucrose | Sigma | S9378 |
Paper clip | Office product | |
15 ml tube | Corning | 430052 |
Red blood cells (RBC) | Qiagen | 158389 (kit) |
Phosphate Buffer Saline (PBS) | Thermo Scientific | SH30256.01 |
BioSprint 96 DNA Blood Kit (48) | Qiagen | 940054 |
1.7 ml microtubes | Axygen | MCT-175-C |
Human Immuno DNA Analysis BeadChip Kit | Illumina | WG-352-1001 |
Bead array reader | Illumina | NA |
GenomeStudio Software | Illumina | N/A |